A safety relay built to wait on purpose was closing up to a second and a half late at a South Carolina nuclear plant, and its maker just traced it to one screw that was threaded all the way in but never tightened, on a part shipped 36 times to six customers

{{author_name}}

Luis Reyes

Nov 25, at 12:10pm ET

A safety relay built to wait on purpose was closing up to a second and a half late at a South Carolina nuclear plant, and its maker just traced it to one screw that was threaded all the way in but never tightened, on a part shipped 36 times to six customers

I went through the NRC’s latest event notification report, and I’ll be honest, most of what’s in there is a wall of part numbers, regulation citations and phone contacts. One update in Tuesday’s batch basically comes down to a single screw.

Back in early July, the H.B. Robinson nuclear plant in Hartsville, South Carolina, put a relay on its test bench and found one set of contacts wasn’t closing when it should. Curtiss-Wright, the company that supplied the part, ran its own tests and measured lags anywhere from 479 to 1,500 milliseconds. That’s somewhere between half a second and a second and a half.

So is a second and a half actually a big deal?

For a light switch, no. But this is a nuclear-qualified timing relay, and with a timing relay, timing is pretty much the whole job. Robinson’s first look was also a bit more confusing than a lag. The plant’s meter read more than 1 megohm across the contacts with the relay’s coil energized, which is basically what you’d see if the contacts hadn’t closed at all. It was only on Curtiss-Wright’s bench that anyone could tell whether they were moving. They were, just slowly.

Robinson’s relay is built to wait on purpose

If you’ve never had a reason to think about relays, here’s the short version. A relay is a switch that gets flipped by electricity instead of a finger. A small current runs through a coil, and the coil moves contacts that open or close a separate circuit.

This one’s an on-delay model, so it’s designed to wait a set amount of time after it gets its signal before it switches. The NRC filing identifies it only as a Tyco relay with part number E7012PB004. Distributor listings for that number describe a double-pole, on-delay timing relay that can be dialed from half a second to five seconds, and TE Connectivity’s catalog lists that E7000 family as nuclear-qualified. Plants generally use relays like this to make things happen in order, so one piece of equipment doesn’t kick in until another has had a moment to get going. Which makes a delay complaint about a delay relay sound a little odd, I’ll admit.

The filing doesn’t say what delay Robinson had the relay set to, or how fast the plant expected those normally open contacts to move, and I couldn’t find that anywhere else either. When the first notice went out, TE was still working out whether the response time counted as acceptable performance or a sign the relay was degrading.

TE traced the lag to one screw

The November 23 update has the answer, and it’s a pretty mundane one. TE Connectivity, the company that used to be Tyco Electronics, found that the screw holding the retainer clip on the relay’s barrel spring was threaded all the way in, with its head sitting flat, but it had never been torqued down. Over time and use, the clip slid fully open. That let the barrel spring stretch out as far as it could go, and TE pinned the slow contacts on that spring adjustment.

Anyone who’s put together a bookshelf knows there’s a difference between a screw that’s in and a screw that’s tight. It turns out a nuclear-qualified relay knows it too.

According to the update, “TE Connectivity determined that this is not a systemic failure.” Still, TE isn’t taking chances. It’s added a second torque check during assembly, so every screw gets verified before a relay is put together. Curtiss-Wright, which supplied the relay with its own tag on it, says it agrees with that assessment. That’s a fairly reasonable fix for a fairly unglamorous problem, and frankly it’s the kind of slip you’d hope a factory catches on the first pass.

All of this ended up on the NRC’s desk because of Part 21, the section of federal nuclear rules that makes suppliers speak up. If a company that makes or sells parts for safety jobs at a nuclear plant finds a defect that could create a substantial safety hazard, it has to tell the NRC, which posts the notice for anyone to read. Curtiss-Wright Flow Control, based in Cincinnati, sent its first notice on September 18, and the NRC lists it as a non-emergency report. If the name sounds familiar, a different part of Curtiss-Wright filed the spare actuator report we covered yesterday.

Six customers got the same part number

Curtiss-Wright says it’s supplied this part number 36 times since 2011, to six different customers. Besides Robinson, which is a single pressurized water reactor run by Duke Energy Progress, the list covers McGuire in North Carolina, Oconee in South Carolina, Fermi in Michigan, PSEG Nuclear’s Hope Creek and Salem plants in New Jersey, and a company called Enhanced Automation.

Shortest lag measured
479 ms
Normally open contacts, Curtiss-Wright bench test.
WORST CASE
Longest lag measured
1,500 ms
A second and a half before the contacts changed state.
Times supplied since 2011
36
Part number E7012PB004, per Curtiss-Wright.
Customers
6
Robinson, McGuire, Oconee, Fermi, PSEG Nuclear and Enhanced Automation.

I’d flag one wrinkle in the wording. The filing says 36 times, not 36 relays, so a single order could’ve covered more than one unit, and the report doesn’t break that down. It also doesn’t say what Enhanced Automation does with the part.

Curtiss-Wright says none of the other customers has reported this defect. What we don’t know is whether any of them has gone looking. I couldn’t find anything in the update asking the other plants to check their stock, and the filing doesn’t say whether Robinson’s relay had ever been installed before it went on the bench. Small mechanical slips show up in these reports more often than you’d think, like the 1.88-inch pulse rod error at Washington State University’s campus reactor, and most of them read a lot like this one once you get past the part numbers.

The full notice sits under Event Number 58455 in the NRC’s November 24 event report, and the rules behind it are in 10 CFR Part 21.

TE says its extra torque check will stay in place for three months or a set number of production runs, depending on demand, and Curtiss-Wright signed off on that plan in the update it filed on November 23.

THE LOTvia The Lot

What do you think?

Sign in with Google when you post
ROOKIE›DRIVER›ENTHUSIAST›EXPERT›LEGEND ★
THE LOTOwner community
Visit →
Luis Reyes

Luis Reyes

With more than 14 years covering the automotive industry, Luis Reyes is a seasoned voice in the field. A law graduate, he channels his curiosity and expertise into the detailed analysis of national and international regulations that shape the automotive world. At Autonocion.com, Luis combines his strong legal background with a deep passion for vehicles — especially those that have left a mark on automotive history. His experience writing for multiple brands across the industry has established him as a trusted authority. Luis is committed to sharing his expertise and enthusiasm with enthusiasts and industry professionals alike, with a firm belief in the continuous evolution and innovation driving the auto industry forward.