{"id":28232,"date":"2026-11-17T12:30:00","date_gmt":"2026-11-17T17:30:00","guid":{"rendered":"https:\/\/www.autonocion.com\/us\/?p=28232"},"modified":"2026-11-17T06:49:13","modified_gmt":"2026-11-17T11:49:13","slug":"1207-megawatt-reactor-washington-shut-down-by-hand-249-both-pumps-blown-fuse","status":"publish","type":"post","link":"https:\/\/www.autonocion.com\/us\/1207-megawatt-reactor-washington-shut-down-by-hand-249-both-pumps-blown-fuse\/","title":{"rendered":"A 1,207-megawatt reactor in Washington state was shut down by hand at 2:49 in the morning after both pumps pushing water through its core tripped five minutes apart, all because one blown fuse knocked out the chillers cooling their drives, and it stayed off the grid for over five days"},"content":{"rendered":"<p>If you&#8217;ve ever lived in an old house, you know the drill. You run one appliance too many, a fuse blows, and half the kitchen goes dark until someone finds a flashlight and a spare.<\/p>\n<p>It turns out a 1,207-megawatt nuclear plant isn&#8217;t completely immune to that kind of problem either. Back on February 12, operators at Columbia Generating Station, about 20 miles north of Richland, Washington, shut the reactor down by hand at 2:49 in the morning after it lost both of its reactor recirculation pumps. And thanks to a revised event report from the plant&#8217;s operator, Energy Northwest, we now know a lot more about why.<\/p>\n<p>That report, <a href=\"https:\/\/www.nrc.gov\/docs\/ML2630\/ML26308A145.pdf\" target=\"_blank\" rel=\"noopener nofollow\">LER 2026-001-01<\/a>, is dated November 4 and showed up in the Nuclear Regulatory Commission&#8217;s public document database on November 13. In February, Energy Northwest&#8217;s explanation to Northwest Public Broadcasting (NWPB) was a faulty electrical filter. The new paperwork points at a fuse. It&#8217;s filed as a supplement to an earlier version, and it doesn&#8217;t say what changed between the two.<\/p>\n<h2>So what do recirculation pumps do?<\/h2>\n<p>Columbia is the Pacific Northwest&#8217;s only commercial nuclear plant, and it&#8217;s a boiling water reactor, a General Electric design the NRC lists as a GE-5. The water boils right inside the reactor core, and the steam goes straight to the turbine.<\/p>\n<p>The recirculation pumps push water through that core, and their speed basically works as the plant&#8217;s throttle. If you want more power, you push more water through, and if you want less, you slow the pumps down. Each pump&#8217;s speed is set by an adjustable speed drive, which is essentially a big electronic motor controller, and at Columbia those drives need their own chillers to stay cool.<\/p>\n<div style=\"display: flex; flex-wrap: wrap; gap: 14px; margin: 24px 0;\">\n<div style=\"flex: 1 1 260px; min-width: 260px; background: #0f172a; color: #f1f5f9; border-radius: 14px; padding: 22px; border: 1px solid #1e293b;\">\n<div style=\"font-size: 11px; letter-spacing: 1.8px; text-transform: uppercase; color: #f87171; margin-bottom: 14px; font-weight: 600;\">Gross output<\/div>\n<div style=\"font-size: 30px; font-weight: 800; line-height: 1; margin-bottom: 6px;\">1,207 MW<\/div>\n<div style=\"font-size: 12px; color: #94a3b8; line-height: 1.4;\">Columbia Generating Station&#8217;s gross electric rating.<\/div>\n<div style=\"font-size: 10px; color: #64748b; line-height: 1.4; margin-top: 10px;\">Source: Energy Northwest<\/div>\n<\/div>\n<div style=\"flex: 1 1 260px; min-width: 260px; background: #0f172a; color: #f1f5f9; border-radius: 14px; padding: 22px; border: 1px solid #1e293b;\">\n<div style=\"font-size: 11px; letter-spacing: 1.8px; text-transform: uppercase; color: #f87171; margin-bottom: 14px; font-weight: 600;\">Pump trips<\/div>\n<div style=\"font-size: 30px; font-weight: 800; line-height: 1; margin-bottom: 6px;\">2:44 \u2192 2:49 a.m.<\/div>\n<div style=\"font-size: 12px; color: #94a3b8; line-height: 1.4;\">Pump 1B tripped first. Pump 1A followed five minutes later, and operators scrammed the reactor by hand.<\/div>\n<div style=\"font-size: 10px; color: #64748b; line-height: 1.4; margin-top: 10px;\">Source: NRC, LER 2026-001-01<\/div>\n<\/div>\n<div style=\"flex: 1 1 260px; min-width: 260px; background: #0f172a; color: #f1f5f9; border-radius: 14px; padding: 22px; border: 1px solid #1e293b;\">\n<div style=\"font-size: 11px; letter-spacing: 1.8px; text-transform: uppercase; color: #f87171; margin-bottom: 14px; font-weight: 600;\">Low-water signals<\/div>\n<div style=\"font-size: 30px; font-weight: 800; line-height: 1; margin-bottom: 6px;\">2 dips below +13 in<\/div>\n<div style=\"font-size: 12px; color: #94a3b8; line-height: 1.4;\">Reactor water level fell below the trip mark twice after the scram, setting off two more scram signals.<\/div>\n<div style=\"font-size: 10px; color: #64748b; line-height: 1.4; margin-top: 10px;\">Source: NRC, LER 2026-001-01<\/div>\n<\/div>\n<div style=\"flex: 1 1 260px; min-width: 260px; background: #0f172a; color: #f1f5f9; border-radius: 14px; padding: 22px; border: 1px solid #1e293b;\">\n<div style=\"font-size: 11px; letter-spacing: 1.8px; text-transform: uppercase; color: #f87171; margin-bottom: 14px; font-weight: 600;\">Run before the scram<\/div>\n<div style=\"font-size: 30px; font-weight: 800; line-height: 1; margin-bottom: 6px;\">227 days<\/div>\n<div style=\"font-size: 12px; color: #94a3b8; line-height: 1.4;\">Straight days online since the last planned refueling outage.<\/div>\n<div style=\"font-size: 10px; color: #64748b; line-height: 1.4; margin-top: 10px;\">Source: Energy Northwest<\/div>\n<\/div>\n<\/div>\n<h2>The pumps didn&#8217;t quit at the same time<\/h2>\n<p>The NRC&#8217;s first event notice made it sound like both pumps dropped out together at 2:49 a.m. Pacific, and it put the loss down to &#8220;abnormal pump drive parameters.&#8221; The revised report is more precise. Pump 1B tripped first, at 2:44 a.m., and the reactor kept running on pump 1A while operators worked through the procedure for a single tripped pump.<\/p>\n<p>Five minutes later, pump 1A tripped too, and operators scrammed the reactor manually. A scram is nuclear shorthand for driving every control rod into the core at once, and according to the report, all of them went in.<\/p>\n<p>I&#8217;d stop short of calling that heroic, though. Energy Northwest has said the plant would&#8217;ve shut itself down automatically if operators hadn&#8217;t, so they basically got there first. That&#8217;s more or less what happened in Arkansas earlier this month, when <a href=\"https:\/\/www.autonocion.com\/us\/988-megawatt-arkansas-reactor-lightning-scram-coolant-pumps-838-am\/\">a reactor lost all its coolant pumps and its protection system tripped it on its own<\/a>. And over the summer, a French plant <a href=\"https:\/\/www.autonocion.com\/us\/reactors-shut-by-hand-jellyfish-four-days\/\">shut reactors down by hand before jellyfish could do it for them<\/a>.<\/p>\n<h2>So was it the filter?<\/h2>\n<p>Mostly no. The narrative in the revised report says the fuses tied to the power supplies for the drives&#8217; cooling system had blown. The report&#8217;s summary adds that the fuse sat in the chiller control panel and failed after overheating for a long time. That cut power to the communication hardware and left the chillers with no way to take commands.<\/p>\n<p>Without their chillers, the drives lost cooling and tripped, and when a drive trips, its pump goes down with it. So one fuse in a control panel ended up taking the whole plant off the grid.<\/p>\n<p>The filter&#8217;s still part of the story, just not as the culprit. As part of the repair, Energy Northwest put in a new fuse holder and new fuses and pulled a power filter out of the drives&#8217; cooling system, which the report describes as unnecessary. I can&#8217;t tell from the report whether that&#8217;s the same filter the company talked about in February, but it&#8217;s pretty easy to see how the two explanations got tangled up.<\/p>\n<p>The alarm&#8217;s arguably the more uncomfortable finding. According to the report, the chiller trouble alarm wasn&#8217;t working, so the control room got no warning that the drives&#8217; cooling was in trouble. The report also says losing power to that chiller panel wasn&#8217;t covered in station procedures, system manuals or training, and getting the chillers back takes someone doing it by hand.<\/p>\n<p>Energy Northwest says it&#8217;s writing procedures for losing chiller function, updating its training material, and checking the chiller for manufacturing defects that could&#8217;ve kept the alarm quiet.<\/p>\n<h2>Then the water level dipped, twice<\/h2>\n<p>Shutting a reactor down doesn&#8217;t mean you&#8217;re done with it, and that&#8217;s where things got a little messy. The fuel keeps putting out heat for a while afterward, which is called decay heat, and the water in the reactor vessel has to stay above a set mark while you get rid of it.<\/p>\n<p>Operators reset the scram at 3:05 a.m. Feedwater pump 1A, which keeps water flowing into the vessel, then started acting up on automatic control, so the crew took the feedwater pumps to manual. A minute later, the level dropped below +13 inches anyway. That reading is a low-water tripwire, and crossing it sends an automatic scram signal. Since every rod was already in, that signal didn&#8217;t really have anything left to do.<\/p>\n<p>Then it happened a second time, and that set off another scram signal. Operators brought the level back up and reset the signal at 3:10 a.m.<\/p>\n<p>Energy Northwest ran a separate investigation into those dips. Apparently the feedwater pump couldn&#8217;t keep up with how fast the reactor vessel was losing pressure. And since the procedures didn&#8217;t explain how to override a high-level lockout on the feedwater system, operators started a controlled depressurization so the condensate booster pumps could help hold the level. That&#8217;s a pretty roundabout way to get there, and the company plans to rewrite those procedures.<\/p>\n<h2>So how did it cool down with both pumps off?<\/h2>\n<p>Frankly, this is the neatest part of the whole report. Columbia got rid of its decay heat through natural circulation. Hot water rises and cooler water sinks on its own, so water keeps moving through the core without any pumps, and the steam went to the main condenser.<\/p>\n<p>The report says every emergency core cooling system was available and that the event never threatened the health and safety of the public or plant staff, which matches what the <a href=\"https:\/\/www.nrc.gov\/reading-rm\/doc-collections\/event-status\/event\/2026\/20260213en.html\" target=\"_blank\" rel=\"noopener nofollow\">NRC&#8217;s event notice<\/a> said back in February.<\/p>\n<h2>The plant was back on the grid more than five days later<\/h2>\n<p>Energy Northwest <a href=\"https:\/\/www.energy-northwest.com\/news-releases\/columbia-generating-station-back-online\/\" target=\"_blank\" rel=\"noopener nofollow\">reconnected Columbia to the regional grid<\/a> on February 17 at about 3:30 p.m. NWPB reported that the plant would come back at roughly 15% of capacity and climb to full power over the following two days or so. The Bonneville Power Administration covered the gap with its hydropower while Columbia was down, according to NWPB.<\/p>\n<p>Before all this, Columbia had run for 227 days straight since its last planned refueling outage, and it <a href=\"https:\/\/www.energy-northwest.com\/news-releases\/columbia-generating-station-offline\/\" target=\"_blank\" rel=\"noopener nofollow\">hadn&#8217;t had an unplanned outage since 2017<\/a>. That&#8217;s a pretty good streak for one fuse to end.<\/p>\n<p>Energy Northwest has Columbia&#8217;s next planned refueling outage scheduled for March 2027, which is the next time the plant is supposed to come off the grid on purpose.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you&#8217;ve ever lived in an old house, you know the drill. You run one appliance too many, a fuse &#8230; <\/p>\n<p class=\"read-more-container\"><a title=\"A 1,207-megawatt reactor in Washington state was shut down by hand at 2:49 in the morning after both pumps pushing water through its core tripped five minutes apart, all because one blown fuse knocked out the chillers cooling their drives, and it stayed off the grid for over five days\" class=\"read-more button\" href=\"https:\/\/www.autonocion.com\/us\/1207-megawatt-reactor-washington-shut-down-by-hand-249-both-pumps-blown-fuse\/#more-28232\" aria-label=\"Read more about A 1,207-megawatt reactor in Washington state was shut down by hand at 2:49 in the morning after both pumps pushing water through its core tripped five minutes apart, all because one blown fuse knocked out the chillers cooling their drives, and it stayed off the grid for over five days\">Read more<\/a><\/p>\n","protected":false},"author":8,"featured_media":28231,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[116],"tags":[],"class_list":["post-28232","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-energy","resize-featured-image"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.autonocion.com\/us\/wp-json\/wp\/v2\/posts\/28232","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.autonocion.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.autonocion.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.autonocion.com\/us\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.autonocion.com\/us\/wp-json\/wp\/v2\/comments?post=28232"}],"version-history":[{"count":2,"href":"https:\/\/www.autonocion.com\/us\/wp-json\/wp\/v2\/posts\/28232\/revisions"}],"predecessor-version":[{"id":28238,"href":"https:\/\/www.autonocion.com\/us\/wp-json\/wp\/v2\/posts\/28232\/revisions\/28238"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.autonocion.com\/us\/wp-json\/wp\/v2\/media\/28231"}],"wp:attachment":[{"href":"https:\/\/www.autonocion.com\/us\/wp-json\/wp\/v2\/media?parent=28232"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.autonocion.com\/us\/wp-json\/wp\/v2\/categories?post=28232"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.autonocion.com\/us\/wp-json\/wp\/v2\/tags?post=28232"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}